System Specifications
Data sample rate: Minimum 3 seconds
Data upload rate: Typically 1 or 5 minutes
Connection type: WiFi
Power requirements: 5V micro USB
Temperature Specifications
Unit of Measure: °C
Range: -40 – 80°C
Accuracy: +/- 0.5°C at 25°C
Working Range: -40 – 85°C
Humidity Specifications
Unit of Measure: %RH
Range: 0 – 100%RH
Accuracy: +/- 3%RH
Working Range: -40 – 85°C
Light Level Specifications
Unit of Measure: Lux (lx)
Range: 0 – 120000lx
Accuracy: +/- 10%
Working Range: -40 – 85°C
Carbon Monoxide Specifications
Unit of Measure: ppm
Range: 0 – 25ppm
Accuracy: +/- 5%
Working Range: -40 – 85°C
Nitrogen Dioxide Specifications
Unit of Measure: ppm
Range: 0 – 10ppm
Accuracy: +/- 5%
Working Range: -40 – 85°C